26% ছাড়
বিস্তারিত
POCT Analyzer ProMax-25
Description
The POCT Immunofluorescence Quantitative Analyzer is used
cooperatively with special fluor immunoassay reagent strips and applicable to
fluor immunoassay of human body samples. The product can be used for
semiquantitative and quantitative immunoassay of medical, ant epidemic and
scientific research institutions.
Features
·
Ultra-high Sensitivity and
excellent precision.
·
Fast and Flexible, result in
short time.
·
Intelligent QR code management.
·
Real-time data transmission,
compatible with LIS/HIS.
·
Store 10,000 results.
·
Large touch screen LCD display.
Specifications
|
Model |
ProMax-25 |
|
Test Item |
The product is used cooperatively with
immunofluorescence assay kit produced by our company. |
|
Excitation Light Source |
LED |
|
Wavelength Range |
740nm |
|
Test Item Parameter |
The user can read configuration parameters of the
instrument from information card. |
|
Sample Type |
Whole blood, serum, plasma, urine and faeces (subject
to specification of immunofluorescence assay kit) |
|
Delay Test |
Delay test time can be set. Place test card in the
instrument and test at fixed time after completion of reaction |
|
Test Speed |
240 times/hour |
|
Background Number |
Fluorescence value should be ≤5 |
|
Repeatability |
The variable coefficient of fluorescence value of
fluorescence test cards of different intensities repeatedly measured by
the instrument CV≤2.0% |
|
Stability |
The relative deviation between the test result at 4th
hour and the 8th hour
after the instrument is working stably and the test result when the
instrument just works stably is limited to ±3.0%. |
|
Accuracy |
When the instrument tests the calibrated fluorescence
test card, the deviation between the measured fluorescence value and the
calibration value of the fluorescence test card is ±3.0%. |
|
Measuring Time |
The time from inserting the fluorescence test card to
displaying the test result should not exceed 15s. |
|
Linearity Range |
Within the concentration range of standards no less
than two orders of magnitudes, the linearly dependent coefficient of
the fluorescence value and concentration read by the
instrument r≥0.990 |
|
Electricity |
AC 100V-240V 50Hz/60Hz; Host: DC12V 5A |
|
Input Power |
60 VA |
|
Dimension |
200*300*140mm |
|
Net Weight |
2.0kg |